Turning insert, d 12.7 mm, s 4.76 mm, corner radius 0.4 mm, grade PH2G115

SNMG120404-MR5D · PH2G115

Palbit logo Parameters from Palbit Catalogue 2024, page C-524

Parameters

dInscribed circle
12.7 mm
sThickness
4.76 mm
rεCorner radius
0.4 mm
Chipbreaker
MR
Grade
PH2G115

Source: Palbit Catalogue 2024, page C-524. The catalog prints no symbols for this table; the symbols are the usual ISO ones.

More parameters 5
Clearance angle
0°
Corner angle
90°
Application range (ISO 513)
P10-P25
Cutting direction
not stated
Rake
negative

Some values are worked out from the printed ones.

Other sizes of the series 108

Code d, mms, mmrε, mmChipbreakerGrade
SNMA090308L5 9.5253.180.8PH5705
SNMA090308L6 9.5253.180.8PH5320
SNMA120404L5 12.74.760.4PH5705
SNMA120404L6 12.74.760.4PH5320
SNMG120404-MF1D 12.74.760.4MFPH2G125
SNMG120404-MF5D 12.74.760.4MFPH2G115
SNMG120404-MFR2 12.74.760.4MFPHG115
SNMG120404-MFR3 12.74.760.4MFPHG125
SNMG120404-MR1D 12.74.760.4MRPH2G125
SNMG120404-MR5D 12.74.760.4MRPH2G115
SNMG120404-MRL9 12.74.760.4MRPH5740
SNMG120404-MRR2 12.74.760.4MRPHG115
SNMG120404-MRR3 12.74.760.4MRPHG125
SNMG120404-PM1D 12.74.760.4PMPH2G125
SNMG120404-PM5D 12.74.760.4PMPH2G115
SNMG120404-PMR3 12.74.760.4PMPHG125
SNMG120404-PMT6 12.74.760.4PMPHG105
SNMG120404-SFG1 12.74.760.4SFPH7910
SNMG120404-SFU4 12.74.760.4SFPHS215
SNMG120404-SFX6 12.74.760.4SFPHH910
SNMG120404-SFY3 12.74.760.4SFPHH920
SNMA120408L5 12.74.760.8PH5705
SNMA120408L6 12.74.760.8PH5320
SNMG120408-GSX6 12.74.760.8GSPHH910
SNMG120408-GSY3 12.74.760.8GSPHH920
SNMG120408-MF1D 12.74.760.8MFPH2G125
SNMG120408-MF5D 12.74.760.8MFPH2G115
SNMG120408-MFR2 12.74.760.8MFPHG115
SNMG120408-MFR3 12.74.760.8MFPHG125
SNMG120408-MR1D 12.74.760.8MRPH2G125
SNMG120408-MR5D 12.74.760.8MRPH2G115
SNMG120408-MRL9 12.74.760.8MRPH5740
SNMG120408-MRR2 12.74.760.8MRPHG115
SNMG120408-MRR3 12.74.760.8MRPHG125
SNMG120408-MRV5 12.74.760.8MRPHG140
SNMG120408-PM1D 12.74.760.8PMPH2G125
SNMG120408-PM5D 12.74.760.8PMPH2G115
SNMG120408-PMR2 12.74.760.8PMPHG115
SNMG120408-PMR3 12.74.760.8PMPHG125
SNMG120408-PMT6 12.74.760.8PMPHG105
SNMG120408-SFG1 12.74.760.8SFPH7910
SNMG120408-SFG4 12.74.760.8SFPH7920
SNMG120408-SFU4 12.74.760.8SFPHS215
SNMG120408-SFX6 12.74.760.8SFPHH910
SNMG120408-SFY3 12.74.760.8SFPHH920
SNMA120412L5 12.74.761.2PH5705
SNMA120412L6 12.74.761.2PH5320
SNMG120412-GSX6 12.74.761.2GSPHH910
SNMG120412-GSY3 12.74.761.2GSPHH920
SNMG120412-MF1D 12.74.761.2MFPH2G125
SNMG120412-MF5D 12.74.761.2MFPH2G115
SNMG120412-MFR2 12.74.761.2MFPHG115
SNMG120412-MFR3 12.74.761.2MFPHG125
SNMG120412-MR1D 12.74.761.2MRPH2G125
SNMG120412-MR5D 12.74.761.2MRPH2G115
SNMG120412-MRR2 12.74.761.2MRPHG115
SNMG120412-MRR3 12.74.761.2MRPHG125
SNMG120412-MRV5 12.74.761.2MRPHG140
SNMG120412-PM1D 12.74.761.2PMPH2G125
SNMG120412-PM5D 12.74.761.2PMPH2G115
SNMG120412-PMR2 12.74.761.2PMPHG115
SNMG120412-PMR3 12.74.761.2PMPHG125
SNMG120412-PMT6 12.74.761.2PMPHG105
SNMG120412-SFG1 12.74.761.2SFPH7910
SNMG120412-SFG4 12.74.761.2SFPH7920
SNMG120412-SFU4 12.74.761.2SFPHS215
SNMG120412-SFX6 12.74.761.2SFPHH910
SNMG120412-SFY3 12.74.761.2SFPHH920
SNMA120416L5 12.74.761.6PH5705
SNMA120416L6 12.74.761.6PH5320
SNMG120416-GSX6 12.74.761.6GSPHH910
SNMG120416-GSY3 12.74.761.6GSPHH920
SNMG120416-MR1D 12.74.761.6MRPH2G125
SNMG120416-MR5D 12.74.761.6MRPH2G115
SNMG120416-MRL9 12.74.761.6MRPH5740
SNMG120416-MRR3 12.74.761.6MRPHG125
SNMA150412L5 15.8754.761.2PH5705
SNMA150412L6 15.8754.761.2PH5320
SNMG150608-MR1D 15.8756.350.8MRPH2G125
SNMG150608-MR5D 15.8756.350.8MRPH2G115
SNMG150608-MRR2 15.8756.350.8MRPHG115
SNMG150608-MRR3 15.8756.350.8MRPHG125
SNMG150608-MRV5 15.8756.350.8MRPHG140
SNMA150612L5 15.8756.351.2PH5705
SNMA150612L6 15.8756.351.2PH5320
SNMG150612-MR1D 15.8756.351.2MRPH2G125
SNMG150612-MR5D 15.8756.351.2MRPH2G115
SNMG150612-MRR2 15.8756.351.2MRPHG115
SNMG150612-MRR3 15.8756.351.2MRPHG125
SNMG150612-MRV5 15.8756.351.2MRPHG140
SNMG150616-MR1D 15.8756.351.6MRPH2G125
SNMA190612L5 19.056.351.2PH5705
SNMA190612L6 19.056.351.2PH5320
SNMG190612-MR1D 19.056.351.2MRPH2G125
SNMG190612-MR5D 19.056.351.2MRPH2G115
SNMG190612-MRL9 19.056.351.2MRPH5740
SNMG190612-MRV5 19.056.351.2MRPHG140
SNMA190616L5 19.056.351.6PH5705
SNMA190616L6 19.056.351.6PH5320
SNMG190616-MR1D 19.056.351.6MRPH2G125
SNMG190616-MR5D 19.056.351.6MRPH2G115
SNMG190616-MRR3 19.056.351.6MRPHG125
SNMG190616-MRV5 19.056.351.6MRPHG140
SNMA190624L5 19.056.352.4PH5705
SNMA190624L6 19.056.352.4PH5320
SNMA250724L5 25.47.942.4PH5705
SNMA250724L6 25.47.942.4PH5320
SNMA25072425 25.47.942.4PH0705

Cutting data

As the manufacturer prints them. The site works nothing out. Palbit, Palbit Catalogue 2024, p. C-525, C - 863, C - 864.

The manufacturer's recommended cutting data for this item

Cutting Conditions Condições de Corte Condiciones de Corte
AP (mm) FN (mm/rev)
MIN MAX MIN MAX
SNMG 120404-MR 3,00 0,40 6,00 0,20 0,10 0,30
Open the catalog page. The table is marked on the page.

The manufacturer's recommended cutting data for this item

CUTTING SPEED (m/min) / Velocidade de corte (m/min) | Velocidad de corte (m/min)
P
Grade fn (mm/r) HB (brinell) CVD Coating Wear Resistence Toughness
NEW PH2G115
0.2 0.4 0.8
P · Unalloyed steel 125-170 285-400 205-310 195-250
P · Low-alloy steel 180-350 215-285 195-260 160-205
P · High-alloy steel 200-325 155-250 135-235 125-230
Open the catalog page. The table is marked on the page.

The manufacturer's recommended cutting data for this item

CHIP BREAKER SPECIFICATIONS
Cutting Conditions** Available Shapes
Feed Fn (mm/rev) Deph of cut DOC (mm) KN _ _ CN _ _ DN _ _ RN _ _ SN _ _ TN _ _ VN _ _ WN _ _
- NEGATIVES - double side · Medium Finishing · M · MR 0,10 to 0,70 0,30 to 9,00

Notes: * T-Land varies according to the IC (IC reference used: 12,7mm) ** Cutting Conditions varies according to the Insert shape, IC and Nose Radius

Open the catalog page. The table is marked on the page.
Open the price request

We reply with price and delivery time.

Palbit SNMG120404-MR5D, photo from the catalog
Photo of the series from Palbit Catalogue 2024, page C-524.
Palbit Catalogue 2024, page C-524. The row of this position is marked. Leaf the catalog

Delta analogs 20

  • SNMG120404MF TCPP15 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MF TCPP25 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MR TCPP15 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MR TCPP25 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MR TCU515 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MR TCU540 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404PM TCPP15 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404PM TCPP25 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MF TCU515 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404MF TCU525 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-FMCTN15 Canela Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MF1D · PH2G125 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MF5D · PH2G115 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MFR2 · PHG115 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MFR3 · PHG125 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MR1D · PH2G125 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MRR2 · PHG115 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-MRR3 · PHG125 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-PM1D · PH2G125 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
  • SNMG120404-PM5D · PH2G115 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder

Check the execution and the hand before ordering; we confirm with the price.

100%