Turning insert, d 12.7 mm, s 6.35 mm, corner radius 1.2 mm, grade PHS225
1123756U5 · PHS225series DNMG
Parameters
- dInscribed circle
- 12.7 mm
- sThickness
- 6.35 mm
- rεCorner radius
- 1.2 mm
- Grade
- PHS225
Source: Palbit Catalogue 2024, page C-514. The catalog prints no symbols for this table; the symbols are the usual ISO ones.
More parameters 3
- Coating
- CVD
- Application range (ISO 513)
- M15-M30
- Cutting direction
- not stated
Some values are worked out from the printed ones.
Other sizes of the series 18
| Code | d, mm | s, mm | rε, mm | Grade |
|---|---|---|---|---|
| 1123749U5 | 9.525 | 4.76 | 0.4 | PHS225 |
| 1121499R3 | 9.525 | 4.76 | 0.8 | PHG125 |
| 1123750U5 | 9.525 | 4.76 | 0.8 | PHS225 |
| 1121502G1 | 12.7 | 4.76 | 0.4 | PH7910 |
| 1121502R3 | 12.7 | 4.76 | 0.4 | PHG125 |
| 1123751U5 | 12.7 | 4.76 | 0.4 | PHS225 |
| 1121504G1 | 12.7 | 4.76 | 0.8 | PH7910 |
| 1121504R3 | 12.7 | 4.76 | 0.8 | PHG125 |
| 1123752U5 | 12.7 | 4.76 | 0.8 | PHS225 |
| 1121507R3 | 12.7 | 4.76 | 1.2 | PHG125 |
| 1123753U5 | 12.7 | 4.76 | 1.2 | PHS225 |
| 1121515R3 | 12.7 | 6.35 | 0.4 | PHG125 |
| 1123754U5 | 12.7 | 6.35 | 0.4 | PHS225 |
| 1121516G1 | 12.7 | 6.35 | 0.8 | PH7910 |
| 1121516R3 | 12.7 | 6.35 | 0.8 | PHG125 |
| 1123755U5 | 12.7 | 6.35 | 0.8 | PHS225 |
| 1121517R3 | 12.7 | 6.35 | 1.2 | PHG125 |
| 1123756U5 | 12.7 | 6.35 | 1.2 | PHS225 |
Cutting data
As the manufacturer prints them. The site works nothing out. Palbit, Palbit Catalogue 2024, p. C-515, C - 863, C - 864.
The manufacturer's recommended cutting data for this item
Cutting Conditions Condições de Corte Condiciones de Corte
| AP (mm) | FN (mm/rev) | |||||
|---|---|---|---|---|---|---|
| MIN | MAX | MIN | MAX | |||
| DNMG 150612-SF | 1,50 | 0,60 | 3,00 | 0,35 | 0,15 | 0,55 |
Open the catalog page. The table is marked on the page. The manufacturer's recommended cutting data for this item
CUTTING SPEED (m/min) / Velocidade de corte (m/min) | Velocidad de corte (m/min) / P
| M | |||||||
|---|---|---|---|---|---|---|---|
| Grade fn (mm/r) HB (brinell) | CVD Coating Wear Resistence Toughness | ||||||
| PHS225 | |||||||
| 0.2 | 0.4 | 0.6 | |||||
| M · SS - Ferritic/martensitic | 200-330 | 115-230 | 90-180 | 70-160 | |||
| M · SS - Austenitic | 180-330 | 110-225 | 85-175 | 65-155 | |||
| M · SS - Austenitic-ferritic (Duplex) | 230-260 | 100-215 | 75-165 | 55-145 | |||
Open the catalog page. The table is marked on the page. The manufacturer's recommended cutting data for this item
CHIP BREAKER SPECIFICATIONS
| Cutting Conditions** | Available Shapes | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Feed Fn (mm/rev) | Deph of cut DOC (mm) | KN _ _ | CN _ _ | DN _ _ | RN _ _ | SN _ _ | TN _ _ | VN _ _ | WN _ _ | |
| - NEGATIVES - double side · to Medium to Finishing · M · SF | 0,10 to 0,55 | 0,60 to 3,00 | ||||||||
Notes: * T-Land varies according to the IC (IC reference used: 12,7mm) ** Cutting Conditions varies according to the Insert shape, IC and Nose Radius
Open the catalog page. The table is marked on the page. We reply with price and delivery time.
Delta analogs 20
- DNMG150612SF TCMM15 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SF TCMM25 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCMM15 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCMM25 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCMM40 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCU515 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCU525 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612MF TCU515 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612MF TCU525 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612MS TCM720 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SF TCM720 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SF TCP710 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCM720 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612SS TCP710 Angelo Ghezzi Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- 1121520U5 · PHS225 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; The hand may differ — confirm the hand for your holder
- DNMG150612-SFU4 · PHS215 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612-SSU4 · PHS215 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612-SSV6 · PHS240 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612-GSX6 · PHH910 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
- DNMG150612-GSY3 · PHH920 Palbit Direct analog chipbreaker & grade vary across these; confirm for your operation.; An operating detail differs or needs confirming for your process; The hand may differ — confirm the hand for your holder
Check the execution and the hand before ordering; we confirm with the price.