Solid drill, cutting diameter 19 mm, shank diameter 20 mm
A 01 RECORD DH i Vollhartmetall Mikrokorn Hochleistungs-Spiralbohrer Solid Carbide Micro Grain high performance twist drills
6027TT-19series 6027TT
Parameters
- Cutting diameter
- 19 mm
- Shank diameter
- 20 mm
- Overall length
- 310 mm
- Flute length
- 230 mm
- Point angle
- 140°
Source: ILIX A01 High Performance Drills 2025, page 73.
More parameters 8
- Coating
- TiAlN Futura Plus
- Coolant
- through tool
- Diameter tolerance
- m7
- Hand
- R
- Length class
- 12xD
- Workpiece materials (ISO)
- P, M, K, S, H
- Shank
- cylindrical h6
- Cutting material
- solid carbide
Other sizes of the series 11
| Code | Cutting diameter, mm | Shank diameter, mm | Overall length, mm | Flute length, mm | Point angle |
|---|---|---|---|---|---|
| 6027TT-15 | 15 | 16 | 260 | 186 | 140 |
| 6027TT-15.5 | 15.5 | 16 | 260 | 185 | 140 |
| 6027TT-16 | 16 | 16 | 260 | 184 | 140 |
| 6027TT-16.5 | 16.5 | 18 | 285 | 209 | 140 |
| 6027TT-17 | 17 | 18 | 285 | 209 | 140 |
| 6027TT-17.5 | 17.5 | 18 | 285 | 208 | 140 |
| 6027TT-18 | 18 | 18 | 285 | 207 | 140 |
| 6027TT-18.5 | 18.5 | 20 | 310 | 230 | 140 |
| 6027TT-19 | 19 | 20 | 310 | 230 | 140 |
| 6027TT-19.5 | 19.5 | 20 | 310 | 229 | 140 |
| 6027TT-20 | 20 | 20 | 310 | 228 | 140 |
Cutting data
As the manufacturer prints them. The site works nothing out. ILIX, ILIX A01 High Performance Drills 2025, p. 128–129.
The manufacturer's recommended cutting data for this item
SCHNITTDATEN | CUTTING DATA | VHM-Hochleistungs-Spiralbohrer | Solid Carbide high performance twist drills | A | 01
| Niedriglegierter Stahl | Mittellegierter Stahl | Hochlegierter Stahl | Rostfreier Stahl | Graues Gusseisen | Sphäroguss | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Low-Alloyed Steel | Medium-Alloyed Steel | High-Alloyed Steel | Martensitisch/Ferritisch | Austenitisch | Grey cast iron | Nodular cast iron | ||||||||
| <800 N/mm 2 | 700/1000 N/mm 2 | 1000/1300 N/mm 2 | Stainless steel | Stainless steel | K1 | K2 | ||||||||
| P1 | P2 | P3 | Martensitic/Ferritic | Austenitic | V c | f | V c | f | ||||||
| V c | f | V c | f | V c | f | M1 | M2 | |||||||
| V c | f | V c | f | |||||||||||
| 6027TT | 115 | 6 | 80 | 6 | 60 | 5 | 45 | 3 | 30 | 2 | 100 | 6 | 80 | 5 |
| Aluminium und | Nicht eisenhaltige Materialien | Titan und Titanlegierungen | HRSA | Gehärtete Stähle | ||||||||||
| Aluminiumlegierungen | Non ferrous materials | Titanium and Titanium alloys | Hitzebeständige Legierungen | Hardened steels | ||||||||||
| Aluminum and Aluminum alloys | N2 | S1 | Heat resistant alloys | 38/48 HRC | 48/58 HRC | 58/68 HRC | ||||||||
| N1 | V c | f | V c | f | S2 | H1 | H2 | H3 | ||||||
| V c | f | V c | f | V c | f | V c | f | V c | f | |||||
| 6027TT | - | - | - | - | 25 | 2 | 45 | 3 | 10 | 1 | - | - | - | - |
Legend: Empfohlen | SuggestedMöglich | Possible
Open the catalog page. The table is marked on the page. Cutting data from a section of the catalog
Vorschub f n (mm/U) für VHM-Hochleistungs-Spiralbohrer | Feed f n (mm/rev) for solid carbide drills
| Ø 2 | Ø 3 | Ø 4 | Ø 5 | Ø 6 | |
|---|---|---|---|---|---|
| 1 | 0,008 | 0,010 | 0,020 | 0,030 | 0,040 |
| 2 | 0,015 | 0,020 | 0,030 | 0,040 | 0,050 |
| 3 | 0,020 | 0,030 | 0,040 | 0,050 | 0,060 |
| 4 | 0,030 | 0,040 | 0,050 | 0,060 | 0,070 |
| 5 | 0,040 | 0,060 | 0,080 | 0,100 | 0,120 |
| 6 | 0,050 | 0,080 | 0,120 | 0,140 | 0,170 |
| 7 | 0,070 | 0,100 | 0,150 | 0,180 | 0,200 |
| 8 | 0,090 | 0,120 | 0,170 | 0,200 | 0,220 |
Open the catalog page. The table is marked on the page. Cutting data from a section of the catalog
cutting data from the manufacturer's catalogue section — ILIX, ILIX A01 High Performance Drills 2025, p. 129
| Ø 8 | Ø 10 | Ø 12 | Ø 16 | Ø 20 | |
|---|---|---|---|---|---|
| 1 | 0,050 | 0,060 | 0,070 | 0,090 | 0,120 |
| 2 | 0,060 | 0,070 | 0,085 | 0,110 | 0,125 |
| 3 | 0,070 | 0,090 | 0,110 | 0,130 | 0,150 |
| 4 | 0,100 | 0,120 | 0,140 | 0,160 | 0,200 |
| 5 | 0,140 | 0,180 | 0,200 | 0,240 | 0,280 |
| 6 | 0,190 | 0,230 | 0,280 | 0,350 | 0,400 |
| 7 | 0,250 | 0,300 | 0,350 | 0,400 | 0,500 |
| 8 | 0,270 | 0,320 | 0,370 | 0,450 | 0,550 |
Open the catalog page. The table is marked on the page. Open the price request
We reply with price and delivery time.
Delta analogs 20
- 6028TT-19 ILIX Direct analog Diameter and length class match, and the coolant and material conditions pass. Shank, coolant supply, grade, coating, setup instructions and cutting data may differ - confirm against the catalogue page
- 6025TT-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing
- 6026TT-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing
- 1181157Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; Without internal coolant, while the original drill has it; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 1181243Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 6060051900 Helion Close analog Compatibility is checked only roughly; Without internal coolant, while the original drill has it; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 6068051900 Helion Close analog Compatibility is checked only roughly; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 6178051900 Helion Close analog Compatibility is checked only roughly; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 1182176Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The shank differs (form, diameter or tolerance); The tolerance class differs, or is not printed for one of the tools
- 6017TT-19 ILIX Close analog Without internal coolant, while the original drill has it; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing
- 6020TF-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing
- 6022TF-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing
- 6018TT-19 ILIX Close analog Without internal coolant, while the original drill has it; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing
- 6021TF-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing
- 6522TN-19 ILIX Close analog Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The point geometry differs; Base material differs (HSS against carbide): use the analog's own cutting data; The tolerance class differs, or is not printed for one of the tools
- 1180953Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; Without internal coolant, while the original drill has it; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 1181059Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 6060031900 Helion Close analog Compatibility is checked only roughly; Without internal coolant, while the original drill has it; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 6068031900 Helion Close analog Compatibility is checked only roughly; Compared by ISO material groups only, not by grade; A different length class (L/D); Some of the required data are missing; The tolerance class differs, or is not printed for one of the tools
- 1181960Z9 · PHU920 Palbit Close analog Compatibility is checked only roughly; Without internal coolant, while the original drill has it; The grade of one of the tools is not known; Compared by ISO material groups only, not by grade; A different length class (L/D); The analog is not printed for every material group or hardness of the original; Some of the required data are missing; The shank differs (form, diameter or tolerance); The tolerance class differs, or is not printed for one of the tools
Check the execution and the hand before ordering; we confirm with the price.